Product List
#
Contact Us

Anthone Electronics Co., Ltd.
You can Tel : 0086-592-6304060
Fax: 0086-592-6304008
Email:
anthone@anthone.com.cn

Address: Building 19, Wanghai Road, Software Park, Xiamen city, China.




Home > Products > Pressure Transmitter >LU-CGP Pressure Transmitter-Pressure Transmitter

LU-CGP Pressure Transmitter-Pressure Transmitter

LU-CGP Pressure Transmitter
LU-CGP Pressure Transmitter  

Technical parameter
 to subject: liquid, gas or vapour
range ability: please contact us
 output: 4-20mA DC
power: 24VDC, it can be 12VDC if non-load, max. is 45VDC
 

1)Technical parameter
 1.1 to subject: liquid, gas or vapour
 1.2 range ability: please contact us
 1.3 output: 4-20mA DC
 1.4 power: 24VDC, it can be 12VDC if non-load, max. is 45VDC
 1.5 positive and negative transfer: up and low may not exceed the range limit after positive and negative transfer, whatever the output is.
 Max. positive transfer: 500% of the min. span.
 Max. negative transfer: 600% of the min. span.
 1.6 Temperature:
temperature of operating for amplifier: -25 ~ +90 degree
temperature of operating for sensor: -40 ~ +104 degree
 1.7 relative humidity: 0 ~ 100%
 1.8 sensor capacity changes: <0.16cm^3
 1.9 indicate meter (field): scale gauge length: 30mm; grade: 2.5
 2.0 isolating explosion: ds II BT5, Intrinsically-safety: ia II CT5
 2.1 span and zero: external continually adjusted
 2.2 over-pressure:
     0 (absolute pressure) - 14Mpa, when range<6Mpa;
     0 (absolute pressure) -32Mpa, when range<20Mpa;
     0 (absolute pressure) - 52Mpa, when range<42Mpa
No damage for transmitter but may cause zero shift, suggest not to operate over-pressure, the max. pressure is 60Mpa for flange template.
 2.3 damp: continually adjusted when time constant is between 0.2 ~ 1.67s.
 2.4 setting time: 2s
2) Performace Index (Note: test under the condition of none shift, max. range status of sensor,

316L stainless isolating disaphargm and other standard condition)
  2.1 Accuracy:+/-0.25% of the span, including the synthesize errors of linear, change-difference

and repeat.
  2.2 Stability:+/-0.25% of max. range (12 months)
  2.3 Temperature affect:
      Zero error:+/-0.5% / 55 degree, zero & range errors:+/-1.0% / 55 degree, when max. range;
      Zero error:+/-3.0% / 55 degree, zero & range errors:+/-3.5% / 55 degree, when min. range;
      Note: for tpye LU-CGPS-1200 (1300), temperature affect is double times of above.
  2.4 Over-pressure affect:+/-0.25% of max. range (according to permitted over-loads for different

ranges)
  2.5 Vibration affect:+/-0.05% / g of the max. range, when 200Hz, any axis up.
  2.6 Power affect:<0.005% / V of output range
  2.7 Load affect:none affect when voltage>12VDC input to the transmitter.
  2.8 Mounting position affect:may cause zero error max.0.24Kpa, but can be calibrated, none affect
for range.

3) Structure index
  3.1 Structure material:
diaphragm: 316 stainless steel, hastelly C, Monel alloy, Tantalum;
O ring: Fluorin rubber;
Flange & bolt:316 stainless steel;
Fill oil:silicon oil;
Electric shell:low-Cu & aluminum alloy;
Plating of electric shell:toast lacquer of amido, formyl,ethene & colophony;
  3.2 Pressure-impulse connector:
      flange NPT 1/4 (taper pipe screw),(this is the transmitter flange connection);
      connection head screw thread NPT 1/2 (tape pipe screw),(selected)
      integrated needle valve of welded conduit connector(selected)
  3.3 Electrical connector:
      down-lead conduit NPT 1/2 line-through hole;
      electric cable connector (selected);
      explosion-proof connector (selected)
  3.4 Net weight: 2.4kg (exclude the selected parts)

OTHER PRODUCTS
1258686259605528.jpgLU-CAP Absolute Pressure Transmitter1258686357901246.jpgLU-CSP Negative Pressure Transmitter1258686474578165.jpgLU-CDP Differential Pressure Transmitter125868657167241.jpgLU-CDR Micro differential-pressure Transmitter1258686669121505.jpgLU-CHP high static-pressure differential-pressure Transmitter1258686776248606.jpgLU-CDP big differential-pressure Transmitter1258688155371388.jpgLU-CLT flange liquid-level Transmitter1258688203307786.jpgLU-CDP/GP remote flange differential-pressure/pressure Transmitter1258687293327813.jpgLU-K proliferate-silicon pressure Transmitter1258687379514653.jpgLU-L Proliferate-silicon liquid-level Transmitter