Anthone Electronics Co., Ltd.
You can Tel :
0086-592-6304060
Fax:
0086-592-6304008
Email:
anthone@anthone.com.cn
Address:
Building 19, Wanghai Road, Software Park, Xiamen city, China.


Technical parameter
to subject: liquid, gas or vapour
range ability: please contact us
output: 4-20mA DC
power: 24VDC, it can be 12VDC if non-load, max. is 45VDC
1)Technical parameter
1.1 to subject: liquid, gas or vapour
1.2 range ability: please contact us
1.3 output: 4-20mA DC
1.4 power: 24VDC, it can be 12VDC if non-load, max. is 45VDC
1.5 positive and negative transfer: up and low may not exceed the range limit after positive and negative transfer, whatever the output is.
Max. positive transfer: 500% of the min. span.
Max. negative transfer: 600% of the min. span.
1.6 Temperature:
temperature of operating for amplifier: -25 ~ +90 degree
temperature of operating for sensor: -40 ~ +104 degree
1.7 relative humidity: 0 ~ 100%
1.8 sensor capacity changes: <0.16cm^3
1.9 indicate meter (field): scale gauge length: 30mm; grade: 2.5
2.0 isolating explosion: ds II BT5, Intrinsically-safety: ia II CT5
2.1 span and zero: external continually adjusted
2.2 over-pressure:
0 (absolute pressure) - 14Mpa, when range<6Mpa;
0 (absolute pressure) -32Mpa, when range<20Mpa;
0 (absolute pressure) - 52Mpa, when range<42Mpa
No damage for transmitter but may cause zero shift, suggest not to operate over-pressure, the max. pressure is 60Mpa for flange template.
2.3 damp: continually adjusted when time constant is between 0.2 ~ 1.67s.
2.4 setting time: 2s
2) Performace Index (Note: test under the condition of none shift, max. range status of sensor,
316L stainless isolating disaphargm and other standard condition)
2.1 Accuracy:+/-0.25% of the span, including the synthesize errors of linear, change-difference
and repeat.
2.2 Stability:+/-0.25% of max. range (12 months)
2.3 Temperature affect:
Zero error:+/-0.5% / 55 degree, zero & range errors:+/-1.0% / 55 degree, when max. range;
Zero error:+/-3.0% / 55 degree, zero & range errors:+/-3.5% / 55 degree, when min. range;
Note: for tpye LU-CGPS-1200 (1300), temperature affect is double times of above.
2.4 Over-pressure affect:+/-0.25% of max. range (according to permitted over-loads for different
ranges)
2.5 Vibration affect:+/-0.05% / g of the max. range, when 200Hz, any axis up.
2.6 Power affect:<0.005% / V of output range
2.7 Load affect:none affect when voltage>12VDC input to the transmitter.
2.8 Mounting position affect:may cause zero error max.0.24Kpa, but can be calibrated, none affect
for range.
3) Structure index
3.1 Structure material:
diaphragm: 316 stainless steel, hastelly C, Monel alloy, Tantalum;
O ring: Fluorin rubber;
Flange & bolt:316 stainless steel;
Fill oil:silicon oil;
Electric shell:low-Cu & aluminum alloy;
Plating of electric shell:toast lacquer of amido, formyl,ethene & colophony;
3.2 Pressure-impulse connector:
flange NPT 1/4 (taper pipe screw),(this is the transmitter flange connection);
connection head screw thread NPT 1/2 (tape pipe screw),(selected)
integrated needle valve of welded conduit connector(selected)
3.3 Electrical connector:
down-lead conduit NPT 1/2 line-through hole;
electric cable connector (selected);
explosion-proof connector (selected)
3.4 Net weight: 2.4kg (exclude the selected parts)
LU-CAP Absolute Pressure Transmitter
LU-CSP Negative Pressure Transmitter
LU-CDP Differential Pressure Transmitter
LU-CDR Micro differential-pressure Transmitter
LU-CHP high static-pressure differential-pressure Transmitter
LU-CDP big differential-pressure Transmitter
LU-CLT flange liquid-level Transmitter
LU-CDP/GP remote flange differential-pressure/pressure Transmitter
LU-K proliferate-silicon pressure Transmitter
LU-L Proliferate-silicon liquid-level Transmitter